Detection Systems DS7060 Guia do Utilizador

Consulte online ou descarregue Guia do Utilizador para Sistemas de segurança - controlo de acesso Detection Systems DS7060. Detection Systems DS7060 User guide Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 40
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
Detection Systems, Inc., 130 Perinton Parkway, Fairport, New York, USA 14450-9199
(716) 223-4060 • (800) 289-0096 • Fax: (716) 223-9180
Detection Systems PTY Ltd.
Unit 2, The Riverside Centre
148 James Ruse Drive
Parramatta, NSW 2150, Australia
61 2 891 4944 Fax: 61 2 891 5844
Detection Systems Int’l Inc.
19, Rue du 19 Mars-78130
Les Mureaux, France
Phone/Fax: 33 1 34 74 9576
Detection Systems Ltd.
Unit 13-18, 17/F New Commerce Centre
19 On Sum Street, Shatin, N.T.
Hong Kong
852 2635 2815 Fax: 852 2648 7986
Detection Systems PTY Ltd.
Unit 21, 45 Gilby Road
Mount Waverley, Victoria 3149, Australia
61 3 9558 8088 Fax: 61 3 9558 8089
Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide P/N 30658D
Keypad Quick Reference Guide
Turning On (arming) your System
Normal Arming PIN + [On]
Perimeter Arming, no entry delay PIN + [No Entry] [Perimeter Only]
Perimeter Arming, with entry delay PIN + [Perimeter Only]
Maximum Security Arming PIN + [No Entry] [On]
Force Arming PIN + Arming Sequence + [Bypass]
Zone Bypass PIN + [Bypass] followed by the Zone number
Quick Arm [#] + [On]
Turning Off (disarming) your System
PIN + [Off]
Commands for other System Features
Chime Mode PIN + [#] [7]
Zone Test PIN + [#] [8] [1]
Read Alarm History PIN + [#] [8] [9]
Battery Test PIN + [System Reset]
Communicator Test PIN + [#] [8] [2]
Fire Reset PIN + [System Reset]
Fire Trouble PIN + [Off] to silence, PIN + [System Reset] to clear
Remote Program Dial Out PIN + [#] [8] [3]
Remote Program Answer PIN + [#] [8] [6]
Local Battery/Sounder Test PIN + [#] [8] [5]
Error Display PIN + [#] [8] [7]
Error Display Reset PIN + [System Reset]
Clear Zone Bypass PIN + [Bypass] [*] to clear
Guest Code Enable PIN + [#] [8] [4]
NOTE: Examples are shown in Commercial Mode but are valid for any mode.
For a detailed description of keypad commands, see the DS7060 User Guide P/N 29955.
Reference Guide
for the
DS7060 Control/Communicator
Vista de página 0
1 2 3 4 5 6 ... 39 40

Resumo do Conteúdo

Página 1 - DS7060 Control/Communicator

Detection Systems, Inc., 130 Perinton Parkway, Fairport, New York, USA 14450-9199(716) 223-4060 • (800) 289-0096 • Fax: (716) 223-9180Detection System

Página 2 - Table of Contents

Page 10 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide• Keyswitch Toggle: Each time this z

Página 3 - 2.0 SPECIFICATIONS

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 11• Alarm on Short: This zone will alarm when the loop is shorted a

Página 4 - 3.0 ENCLOSURE INSTALLATION

Page 12 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide7.6 Address 06 - Programmed Zone Resp

Página 5 - 4.0 CONTROL TERMINAL WIRING

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 13• Armed: This is an output programmed to activate when the system

Página 6 - 5.0 SYSTEM WORKSHEETS

Page 14 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide7.10 Address 10 - General Control• Si

Página 7

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 157.11 Address 11 - Keypad AssignmentThe keypad type (LED or Alpha)

Página 8 - 7.0 PROGRAMMING THE DS7060

Page 16 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide7.13 Address 19 - Special Keys• Disab

Página 9

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 177.15 Address 21 - Phone Number Control• Dial Pulse: If programmed

Página 10 - 7.3 Address 03 - Zone Action

Page 18 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference GuideREPORTSProgram locations 24 through 3

Página 11 - 7.4 Address 04 - Output Type

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 197.20 Address 26 - Zone Alarm Restoral Report• Zone Alarm Restoral:

Página 12 - 7.8 Address 08 - Outputs

Page 2 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference GuideTable of Contents1.0 SYSTEM OVERVIEW 3

Página 13 - 7.9 Address 09 - User Control

Page 20 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide7.23 Address 29 - Zone Bypass Report•

Página 14

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 217.26 Address 32 - Battery, AC Report• Low Battery Report: This re

Página 15

Page 22 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide7.29 Address 35 - Exit Error, Recent

Página 16

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 237.32 Address 38 - Phone #1 FormatAddress 39 - Phone #2 Format7.33

Página 17 - 7.17 Address 23 - Time Delays

Page 24 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide7.34 Address 46 - Programmer & Ma

Página 18

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 258.0 INSTALLATION GUIDE FOR U. L. LISTED SYSTEMS8.1 DS7060 U. L. Li

Página 19

Page 26 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guideburglary = steady). In all cases, the

Página 20

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 27• Entry Delay Timer (Program Address 23) must be programmed for no

Página 21

Page 28 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide2. Timer Programming:• Entry, Exit De

Página 22

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 293. General Control Programming:• Must be programmed for Swinger Sh

Página 23 - Address 39 - Phone #2 Format

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 31.0 SYSTEM OVERVIEWThe DS7060 Control/Communicator is a fully integ

Página 24

Page 30 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide8.4 Wiring and Programming Informatio

Página 25 - 8.1 DS7060 U. L. Listings

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 3111.0 CANADIAN DEPARTMENT OF COMMUNICATIONS11.1 General Installatio

Página 26 - 8.3 Programming the DS7060

Page 32 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide13.0 REPORT PROGRAMMING13.1 Suggested

Página 27 - Police Station Connection

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 33Personal Dialing and Pager Format4/2 Format (suggested values)(sug

Página 28

Page 34 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide13.3 Values SentHigh Speed 4/9 Format

Página 29

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 35

Página 30 - 9.0 FCC COMPLIANCE NOTICE

Page 36 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference GuideContact ID Format

Página 31 - 11.3 RFI Requirements

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 37SIA FormatSIA reporting allows the installer to select the type of

Página 32 - 13.0 REPORT PROGRAMMING

Page 38 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference GuideDESCRIPTION ADDRESS SECTION PAGE #AC

Página 33 - (suggested values)

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 39IndexSymbols3/1 183/1 with Parity 3, 183/1E 183/1E with Parity

Página 34 - 13.3 Values Sent

Page 4 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide3.0 ENCLOSURE INSTALLATIONThe DS7060 c

Página 35

Page 40 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference GuideProgrammingHOW TO PROGRAM THE DS7060

Página 36 - Contact ID Format

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 54.0 CONTROL TERMINAL WIRINGWARNING: Before servicing this equipment

Página 37 - SIA Format

Page 6 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide5.0 SYSTEM WORKSHEETS

Página 38

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 7

Página 39

Page 8 Copyright © 1996-97 Detection Systems, Inc. DS7060 Reference Guide6.0 HOW TO PROGRAM THE DS7060To enter

Página 40

DS7060 Reference Guide Copyright © 1996-97 Detection Systems, Inc. Page 97.1 Address 01 - Zone ProgrammingA zone is an input to the DS7060 C

Comentários a estes Manuais

Sem comentários