Detection Systems DS7060 Manual do Utilizador Página 18

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 24
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 17
4/98
Page 18 Copyright 1997-98 Detection Systems, Inc. DS7060-AUS Reference Guide
System Trouble:
This report is sent when a
control trouble condition occurs.
System Trouble Restoral:
This report is sent
when all system trouble conditions restore.
Exit Error: This report is sent if an exit error
occurs. An exit error occurs when an entry/exit
zone is still violated at the end of the exit delay. If
this happens, the entry delay will begin. If the
system is not disarmed before the entry delay
expires, an alarm report for the effected zone will
be sent and the Exit Error Report will be sent.
Recent Closing: This report is sent, along with
any alarm reports, when there is an alarm within
the first five minutes after the system has been
armed.
Comm. Failure Report: This report is sent after
the programmed number of communicator
attempts. Refer to Address 22 - Dial Attempts.
Comm. Restore Report: This report is sent after
there has been a communicator failure. Retries will
occur after 30 minutes, then every 24 hours or
when a new event occurs. When the next
successful communicator attempt occurs, this
report will be included.
Automatic Test Report: This report is sent at
fixed intervals determined by programming
Address 48 - Automatic Test Report Interval. By
default, the panel will send the first automatic
report 12 hours after the panel has been powered
up, and from that point on, it will follow the interval
selected by Address 48. The time before the first
Automatic test report is sent can be adjusted
between 1 and 24 hours after the panel has been
powered up by setting Address 49 - Hours to First
Auto Test Report.
Communicator Test Report: This report is sent
as a result of initiating a Communicator Test, a PIN
+ [#] [8] [2] command sequence. Requires that
Addresses 37 “Account Code”, 38 “Phone # 1
Format” and 40 “Phone #1 be programmed.
System Test: This report is sent when a system
test has been started using the [#] [8] [1] key
sequence.
System Test Restoral: This report is sent when
the system test [#] [8] [1] has been completed or
has timed-out.