Bosch Security Systems, Inc. Products Technical Bulletin
TBI 10-19-2007 01 Daylight Saving Time Page 5 © 2007 Bosch Security Systems, Inc.
Standalone Systems
You must use each controller’s faceplate to configure all standalone Readykey controllers not connected to an administration
PC. The programming process used depends on the controller model. Refer to your controller documentation.
K2100/K1100
1. Press and hold the Reset button for two sec. You will hear a short beep followed by a long beep. During the long
beep, press and hold the Reset button for one sec.
2. A PASSWRD field opens on the faceplate screen. Type PAC1990 and press ENT.
3. At the CMD prompt, type C then press ENT.
4. At the DATE prompt, type the correct date, then press ENT + (or NXT, depending on the model of your
faceplate).
5. At the TIME prompt, type the correct time in military format. Press ENT.
6. Press ESC twice.
K2200/K1200
1. Push DIP switch 4 to the right.
2. A PASSWRD field opens on the faceplate screen. Type PAC1990 and press ENT.
3. At the CMD prompt, type C then press ENT.
4. At the DATE prompt, type the correct date, then press ENT + (or NXT, depending on your faceplate).
5. At the TIME prompt, type the correct time in military format. Press ENT.
6. Press ESC twice.
2.4.2 Vision
Controllers connected to Vision software for PC administration synchronize to the PC clock at midnight. Because Daylight
Saving Time adjusts at 02:00, the controller’s internal clock does not reflect the time change. This affects door unlock and
access level schedules. Use the controller software to manually set all controllers. There are two methods for synchronizing
the controller clocks, depending on your system configuration.
CNC Administration
1. Click PAC→Installer.
2. Unlock the module.
3. Click to select the CNC.
4. Right-click to select Controller Commands→Set Date/Time.
5. The Clock Sync command is sent to the CNC. It might take up to five min before the command appears on the
CNC faceplate.
6. Repeat Steps 3 through 5 for each controller on the 6-wire bus.
Modem Sites
1. Click to select the controller.
2. Right-click to select Controller Commands→Connect Controller.
3. When connected, click to select Controller Commands→Set Date/Time.
4. Perform Steps 1 through 3 for each controller connected to the system using a modem.
Administration Kit Administered Systems
1. Click PAC→Installer.
2. Unlock the module.
3. Click to select the controller.
4. Right-click to select Controller Commands→Set Date/Time.
5. Perform Steps 1 through 3 for each controller in the system.